Datasheet
Hardware Manual
For latest firmware and web UI user manual, please contact us.
Lantech I(P)GS-5400-2P-PT is a high-performance L2 + managed industrial Ethernet switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode, multiple VLAN mode with easy configuration. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH v2/SSL, Mac-based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports Cisco Discovery Protocol (CDP) for Ciscoworks to detect the switch info and show on L2 map topology.
The highly flexible modular design consisting of maximum 24x Gigabit T+4xDual SFP,24x Giga PoE at/af (IPGS-5400-2P-PT)+4xDual SFP, 28xGigabit/100M SFP, 18x100M ST/SC + 4 Gigabit SFP covers the widest deployment of applications.
The built-in MMS server allows SCADA to control & monitor switch for data modeling.
Built-in MMS server for IEC61850 data modeling for monitoring and control
The built-in MMS (Manufacturing Messaging Specification) server can help SCADA to monitor and control switch by data modeling. It covers system, power, port status, network configuration.
Enhanced G.8032 ring, 16 MSTI MSTP; MRP ring
Lantech I(P)GS-5400-2P-PT features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI.
MRP (Media Redundancy Protocol) can be supported for industrial automation networks.
Miss-wiring avoidance, Loop protection, Node failure protection
The I(P)GS-5400-2P-PT also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech I(P)GS-5400-2P-PT is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
QoS by VLAN for legacy device
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS and GVRP for large VLAN segmentation.
IGMPv3, GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.
802.1X security by MAC address
MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a port. By authenticating based on the host's source MAC address, the host is not required to run a user for the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC can be registered in the MAC address table of switch.
Reliable network protection, node failure protection
The I(P)GS-5400-2P-PT also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech I(P)GS-5400-2P-PT is able to alert with the LED indicator and send out an email or traps. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 & Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch), it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.
Auto-provisioning for firmware/configuration update
The switch supports auto-provisioning for switch to auto-check the latest software image and configuration through TFTP server.
User-friendly GUI, Auto topology drawing
The user-friendly UI, innovative auto topology drawing and topology demo makes I(P)GS-5400-2P-PT much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.
Editable configuration file
The configuration file of Lantech I(P)GS-5400-2P-PT can be exported and edited with word processor for the other switches configuration with ease. The factory reset button can restore the setting back to factory default. The built-in watchdog design can automatically reboot the switch when CPU is found dead.
Environmental monitoring for switch inside information
The environmental monitoring can detect switch overall temperature, total PoE load, voltage and current where can send the SNMP traps and email when abnormal.
The PoE modules support advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD is hang up then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. It also supports per-port PoE status including current, voltage, watt and temperature information.
Event log & message; 2 DI + 2DO
In case of event, the I(P)GS-5400-2P-PT is able to send an email to pre-defined addresses as well as SNMP Traps out immediately. It provides 2DI and 2DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
Various dual power conversions redundancy, high ESD protection
Lantech I(P)GS-5400-2P-PT chassis and modules are designed for easy maintenance and installation; It also supports dual power redundancies with isolated 100~240VAC/120~370VDC power conversion and isolated 16.8~137.5VDC power conversion to increase the network reliability. It also supports a terminal block for connecting DC 48V PoE power source (IPGS-5400-2P-PT).
Lantech I(P)GS-5400-2P-PT features high reliability and robustness compliant with IEC-61850-3 & IEEE 1613 withstanding extensive EMI/RFI phenomenon, ±4kV surge, inductive load switching, high ESD (±8kV contact/ ±15kV air), 4kV EFT, high fault current environment usually found in Substation, Steel automation, Mining and Process control etc. IGS-5400-2P-E can run under operational temperatures ranging from -40°C~75°C in the harsh and critical environments.
IEEE Standards |
IEEE 802.3 10Base-T Ethernet |
||||||||||||||||||
Switch Architecture |
Back-plane (Switching Fabric): 56Gbps |
||||||||||||||||||
Transfer Rate |
14,880pps for Ethernet port |
||||||||||||||||||
CPU |
Marvell 800Mhz |
||||||||||||||||||
RAM |
256M Byte |
||||||||||||||||||
Flash |
128M Byte |
||||||||||||||||||
MAC Address |
16K MAC address table |
||||||||||||||||||
Jumbo frame |
10KB on all ports |
||||||||||||||||||
Connectors |
Max. 24 10/100/1000T RJ-45 with auto MDI/MDI-X+4 SFP sockets |
||||||||||||||||||
LED |
Per unit: Power 1 (Green), Power 2 (Green), Alarm (Red), R.M (Green) |
||||||||||||||||||
Power Supply |
Two power sockets for the switch system |
||||||||||||||||||
Power Consumption |
17.5 W@DC, 21.5W @VAC |
||||||||||||||||||
PoE Budget |
Max. 720W at rear side with external dual 48VDC input |
||||||||||||||||||
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
||||||||||||||||||
DI/DO |
2 Digital Input (DI) : |
||||||||||||||||||
Case Dimension |
19” Metal case, IP-30; 440mm(W)x325mm(D)x44mm(H) |
||||||||||||||||||
Weight |
2.9 kgs |
||||||||||||||||||
Operating Humidity |
5%~95% (Non-condensing) |
||||||||||||||||||
Operating Temperature |
Standard: -20°C ~60°C |
||||||||||||||||||
Storage Temperature |
-40°C ~85°C |
||||||||||||||||||
EMI & EMS |
FCC Class A,
IEC 61000-4-8 PFMF |
||||||||||||||||||
MTBF |
572,361hrs |
||||||||||||||||||
Stability Testing |
IEC 60068-2-6: 2007 (Vibration) |
||||||||||||||||||
Safety |
EN IEC 62368-1 |
||||||||||||||||||
Railway verification |
EN50121-4 |
||||||||||||||||||
Power Automation |
IEC 61850-3, IEEE 1613, IEC 60255-5 |
||||||||||||||||||
Warranty |
5 years |
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP MIB |
MIB |
ITU G.8032 |
Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (single ring) |
MMS Data Modeling |
|
PoE Management |
PoE Detection to check if PD hangs then restart the PD; PoE configuration; PoE monitoring; PoE Scheduling to On/OFF PD upon routine time table |
Per Port PoE Status |
Enable/Disable, voltage, current, watts, temperature |
User-friendly UI |
|
Port Trunk with LACP |
LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members |
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
CDP |
Cisco Discovery Protocol for topology mapping |
Environmental Monitoring |
System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M model) |
VLAN |
Port Based VLAN |
RSTP/MSTP |
Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree with 16 MSTI |
Quality of Service |
The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4 |
Class of Service |
Support IEEE802.1p class of service, per port provides 8 priority queues |
MLD Snooping |
Support IPv6 Multicast stream |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Port Mirror |
Support 3 mirroring types: “RX, TX and Both packet” |
Network Security |
Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruders. |
IGMP |
Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP, QinQ, QOS by VLAN |
Static MAC-Port bridge |
Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application |
Bandwidth Control |
Support ingress packet filter and egress packet limit. |
RTC |
Built-in Real Time Clock to keep track of time always |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server(RFC3164) |
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
Protection |
|
SNMP Trap |
Up to 10 trap stations; trap types including:
|
DHCP |
Provide DHCP Client/ DHCP Server/DHCP Option 82/Port-based DHCP; DHCP Option 66; DHCP Snooping, basic IPv6 DHCP server |
Mac-based DHCP Server |
Assign IP address by Mac |
DNS |
Provide DNS client feature |
Diagnostic |
Support Ping and DDM information |
SNTP |
Supports Dual NTP server to synchronize system clock in Internet |
Firmware Update |
Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade |
Configuration backup & restore |
Supports text configuration file for system quick installation |
Auto Provision |
To verify switch firmware with the latest or certain version |
P/N | Model name | Description |
---|---|---|
8388-1001TEL | IGS-5400-2P-PT-HV-E | 4 Modular Slots L2 plus Industrial IEC-61850 Switch Chassis Built-in 1x isolated AC/DC 100~240VAC/120V~370VDC power conversion + 1x isolated DC 16.8~137.5VDC power supply; -40°C to 75°C |
8388-1183 | IGS-5400-2P-PT-DCI-E | 4 Modular Slots L2 plus Industrial Switch IEC 61850-3 Chassis Built-in 1x isolated DC 16.8~137.5VDC power supply + 1x optional power socket; -40°C to 75°C |
8388-1301 | IPGS-5400-2P-PT-HV-E | 4 Modular Slots L2 plus Industrial IEC 61853-3 PoE Switch Chassis Built-in 1x isolated AC/DC 100~240VAC/120V~370VDC power conversion + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C |
8388-1384 | IPGS-5400-2P-PT-DCI-E | 4 Modular Slots L2 plus Industrial Switch Chassis Built-in 1x isolated DC 16.8~137.5VDC power supply + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C |
P/N | Model name | Discription |
---|---|---|
8380-1055 | 8x GIGA T Module | 8x 10/100/1000T Module; -40°C to 75°C |
8380-1145 | 8x GIGA T-PoE at/af Module | 8x 10/100/1000T PoE at/af Module; -40°C to 75°C |
8380-1065 | 8x SFP Module | 8x Dual Speed SFP module for 100M SFP or Gigabit SFP; -40°C to 75°C |
8380-1075 | 4x GIGA T + 4x SFP Module | 4x 10/100/1000T + 4 x 100/1000M Dual Speed SFP Module; -40°C to 75°C |
P/N | Model name | Discription |
---|---|---|
8380-1155 | 4x SFP Module | 4x Dual Speed SFP module for 100M SFP or Gigabit SFP; -40°C to 75°C |
Model name | Description |
---|---|
EOTH000701 | Isolation Power 100-240VAC, 120-370VDC 2.0A max, 47-63HZ |
EOTH000708 | Power Input Module 16.8-137.5VDC |
EOTH000709 | Isolation Power 100-240VAC, 120-370VDC 2.0A max, 47-63HZ |
Model name | Description |
---|---|
NDR-480 Series | 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-240 Series | 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-120 Series | 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
NDR-75 Series | 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
Model name | Description | Model name | Description |
---|---|---|---|
8330-162-V1 | MINI GBIC 1000SX (LC/0.5KM) Transceiver | 8330-186-V1 | 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310) |
8330-163-V1 | MINI GBIC 1000SX2 (LC/2KM) Transceiver | 8330-187-V1 | LTSFP-1000BX-20KM Transceiver (WDM 1550) |
8330-165-V1 | MINI GBIC 1000LX (LC/10KM) Transceiver | 8330-180-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1310) |
8340-0591-V1 | MINI GBIC 1000LHX (LC/40KM) Transceiver | 8330-182-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1550) |
8330-166-V1 | MINI GBIC 1000XD (LC/50KM) Transceiver | 8330-181-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1310) |
8330-169-V1 | MINI GBIC 1000XD (LC/60KM) Transceiver | 8330-183-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1550) |
8330-167-V1 | MINI GBIC 1000ZX (LC/80KM) Transceiver | 8330-184-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1490) |
8330-170-V1 | MINI GBIC 1000EZX (120KM) Transceiver | 8330-185-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1550) |
8330-168-V1 | MINI GBIC 10/100/1000T (100m) Transceiver | 8330-071-V1 | 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver |
8330-060-V1 | 100Base FX 2KM, Multi-mode, LC Transceiver | 8330-072-V1 | 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver |
8330-065-V1 | 100Base FX 5KM, Multi-mode, LC Transceiver | 8330-069-V1 | 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver |
8330-061-V1 | 100Base LX 30KM, Single-mode, LC Transceiver | 8330-068-V1 | 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver |
8330-059-V1 | 100Base LX 60KM, Single-mode, LC Transceiver | 8330-080-V1 | 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver |
8330-197-V1 | 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) | 8330-082-V1 | 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver |
8330-198-V1 | 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) | 8330-081-V1 | 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver |
8330-195-V1 | 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) | 8330-083-V1 | 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver |
8330-196-V1 | 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) | 8330-084-V1 | 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver |
8330-188-V1 | 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) | 8330-085-V1 | 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver |
8330-189-V1 | 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) | 8330-191-V1 | Dual Speed SFP 100M/1000M-LX 10KM Transceiver |
All SFP P/N# ended with D are with DDM function |
2020 © Lantech Communications Global, Inc. ALL Rights Reserved. Privacy Policy | Terms of Service