24 10/100/1000T PoE at/af + 4 Dual Speed SFP L2+ Industrial Managed Switch

  • Support IEEE802.3at/af up to 30W per port
  • Support dual power redundancy AC&DC
  • PoE management incl. Detection and Scheduling
  • Enhanced G.8032 ring protection < 20ms for single ring. Supports auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP; support MRP ring
  • Miss-wiring avoidance & Node failure protection (node failure protection)
  • User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI
  • Support LACP link aggregation, IGMP v3/router port, MLD snooping, DHCP server & DHCP Option82; DHCP Snooping, Port based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH v2/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3,TACACS+**, QinQ
  • Protocol based VLAN ; IPv4 Subnet based VLAN
  • Environmental Monitoring for temp., voltage & current
  • USB slot for edited restoration and auto backup


PoE 802.3at/af 30W ITU G.8032 Ring Environmental Monitoring USB FCC CE WEEE RoHS2


Datasheet   Hardware Manual  
For latest firmware and web UI user manual, please contact us.

OVERVIEW

Lantech IPGS-5424 is a high performance L2+ (Gigabit uplink) PoE managed Ethernet switch with 24 10/100/1000T PoE + 4 Dual Speed SFP. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode, multiple VLAN model. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+**, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network.


Compliant with 802.3af/at standard, the Lantech IPGS-5424 is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPGS-5424 supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.


Miss-wiring avoidance, Loop protection, Node failure protection
The IPGS-5424 also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPGS-5424 is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.


Enhanced G.8032 ring, 16 MSTI MSTP; MRP ring
Lantech IPGS-5424 features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI.


MRP (Media Redundancy Protocol) can be supported for industrial automation networks.


DHCP option 82 & Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.


QoS by VLAN for legacy devices
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.


QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.


802.1X security by MAC address
MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a port. By authenticating based on the host's source MAC address, the host is not required to run a user for the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC can be registered in the MAC address table of switch.


IGMPv3,GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.


Auto-provisioning for firmware/configuration update
The switch supports auto-provisioning for switch to auto-check the latest software image and configuration through TFTP server.


User friendly UI, Auto topology drawing, complete CLI
The user friendly UI, innovative auto topology drawing and topology demo makes IPGS-5424 much easier to get hands-on. The IPGS-5424 supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.


Editable configuration file; USB port for configuration upload & download
The configuration file of Lantech IPGS-5424 can be exported and edited with word processor for the other switches configuration with ease. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.


The built-in USB port can have configuration upload & download by USB dongle.


Event log & message; 2 DI / 2 DO
In case of event, the IPGS-5424 is able to send an email to pre-defined addresses as well as SNMP Traps our immediately. It provides 2 DI and 2 DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.


Environmental monitoring for switch inside information
The environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps and email when abnormal.


Various dual power conversions redundancy; Relay contact alarm
Lantech IPGS-5424 supports dual power redundancies with isolated 100~240VAC/120~370VDC power conversion and isolated 36~75VDC power conversion or with non-isolated 12~56VDC power module to increase the network reliability. It also supports terminal block for connecting DC 48V PoE power source. Featured with relay contact alarm function, the IPGS-5424 is able to connect with alarm system in case of power failure. The IPGS-5424 also provides ±4000V EFT, ±4000V Surge and ±8000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.


Industrial hardened design for extended temperature operation
Lantech IGS-5424-PT features high reliability and robustness withstanding extensive EMI/RFI phenomenon, lighting surge, inductive load switching, high ESD, high fault current environment, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.


Lantech IPGS-5424 can run under widely operational temperature (-40°C~75°C) in the harsh environment.


*Future Release
**Optional
***Optional DDM SFP required

FEATURES

  • 24 10/100/1000T + 4 Dual Speed SFP w/24 PoE 802.3af/at ports (Total 28 Ports Switch)
  • Embedded 24 PoE ports IEEE802.3af/at function to feed power up to 30W@54V; 15W @ 48V per port for active operation
  • PoE management including PoE detection and scheduling for PD (power devices)
  • Back-plane (Switching Fabric): 56Gbps
  • 16K MAC address table
  • DDM to support SFP diagnostic function***
    • Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
  • 10KB Jumbo frame supported on all ports
  • User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
  • Enhanced G.8032 Ring protection in 20ms for single ring
    • Support various ring/chain topologies, including dynamic coupling ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Ring covers multicast on different ports
  • Dual isolated power conversions for 1600V DC(36V~75V)
  • Dual isolated power conversions for ±3000 V (100~240VAC/120~370VDC)
  • Dual power supply terinal block for non-isolated power DC(12V~56V)
  • Rear terminal block for PoE power source(DC48V)
  • Provides EFT protection ±4000 VDC for power line.
  • Supports ±8000 VDC Ethernet ESD protection
  • LACP load balancing to distribute the load*
  • Built-in RTC (Real Time Clock) to keep track of time
  • Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority
  • IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy
  • 4K 802.1Q VLAN, Port based VLAN, GVRP, QinQ
  • Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console
  • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server; Port based DHCP server; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server
  • Mac based DHCP server to assign IP address
  • MLD Snooping for IPv6 Multicast stream
  • Bandwidth Control
    • Ingress packet filter and egress rate limit
    • Broadcast/multicast packet filter control
  • Relay alarm output system events
  • Miss-wiring avoidance
    • LED indicator
    • Email or traps notification
  • Node failure protection
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • TFTP/HTTP firmware upgrade; USB for edited restoration and auto backup
  • System Event Log and SNMP Trap for alarm support; 32 RMON counters
  • Security
    • SSL/SSH v2/INGRESS/EGRESS ACL L2/L3
    • MAC address table: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • Management access control with priority
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
    • TACACS+**
  • Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application
  • IGMP router port to assign query in ring and for reversed multicast video flow
  • Multicast VLAN registration* for metro video
  • IGMPv1,v2,v3 with Query mode for multi media; GMRP
  • Factory reset button to restore setting to factory default
  • Watchdog design to auto reboot switch CPU is found dead
  • Diagnostic including Ping / DDM information
  • Environmental monitoring for system input voltage, current, ambient temperature
  • Supports DIDO (Digital Input/Digital Output)
  • IP30 metal housing with DIN rail and Wall-mount** design
  • Auto Provision to verify switch firmware with the latest or certain version
*Future Release
**Optional
***Optional DDM SFP required

SPECIFICATIONS

Hardware Specifications

IEEE Standards

IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Ethernet
IEEE 802.3ab 1000Base-T Ethernet
IEEE802.3z Gigabit fiber
IEEE 802.3x Flow Control Capability
ANSI/IEEE 802.3 Auto-negotiation
IEEE 802.1Q VLAN
IEEE 802.1p Class of Service
IEEE 802.1X Access Control
IEEE 802.1D Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1x User Authentication (Radius)
IEEE 802.3t/af Power Over Ethernet

Switch Architecture

Back-plane (Switching Fabric): 56Gbps

Transfer Rate

14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port

CPU

Marvell 800Mhz

RAM

256M Byte

Flash

128M Byte

Mac Address

16K MAC address table

Jumbo frame

10KB*

PoE pin assignment

RJ-45 port # 1~# 24 support PoE at/af End-point,
Alternative A mode. Per port provides up to 30W@54V capability.
Positive (VCC+): RJ-45 pin 1,2.
Negative (VCC-): RJ-45 pin 3,6.

PoE input voltage & Power feed voltage

Input V

Active Mode A /Output V

45~56V(af)

48V@15W

54~56V(at)

54V@30W

Connectors

24 10/100/1000T RJ-45 with auto MDI/MDI-X function
4 100M / 1000M Mini-GBIC : SFP sockets
RS-232 console: Female DB-9
USB for automatic backup and restore

DDM

Conform to SFF-8472 to show diagnostic SFP with temperature, current, voltage, input and output power

Protocol

CSMA/CD

LED

Per unit: Power 1 (Green), Power 2 (Green), Fault (Red) ,R.M (Green)                                       
Link/Activity (Green), Full duplex/collision(Yellow)), MINI GBIC (Link/Activity )(Green) 

Power Supply

AC model: 100~240V AC IEC320 conversion X1

DC model: 12~56VDC INPUT X1

PoE power: dual input for 45~56VDC

Additional power socket (optional):

  1. 100-240VAC, 120-370VDC
  2. 36-75VDC
  3. 100-240VAC IEC320
  4. 12-56VDC

Power Consumption

Full load: 30W/ Unload: 13W

PoE Power Budget

Max 720W (from separate PoE power supply) (50-56VDC input is recommended for 802.3at 30W applications)
Higher PoE budget can be applied upon request. **

Relay Alarm

Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V

DI/DO

2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA

Case Dimension

19” Metal case,IP-30; 440mm(W)x325mm(D)x44mm(H)

Weight

2.9 kgs

Operating Humidity

5%~95% (Non-condensing)

Operating Temperature

Standard: -20°C ~60°C
-E model: -40°C ~75°C

Storage Temperature

-40°C ~85°C

EMI

FCC Class A, CE EN61000-4-2 (ESD),
CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT),
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS),
CE EN61000-4-8, CE EN61000-4-11,
CE EN55032 Class A, CE EN55024

Safety

EN IEC 62368-1

Railway verification

EN50121-4

MTBF

586,450 hours

Warranty

5 years

Software Specifications

Management

SNMP v1 v2c, v3/ Web/Telnet/CLI

SNMP MIB

MIB
MIBII
SNMP MIB
Bridge MIB
IF MIB
RMON MIB
Private MIB

VLAN

Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096)
GVRP, QinQ, Protocol based VLAN; IPv4 Subnet based VLAN

Port Trunk with LACP

LACP Port Trunk: 8 Trunk groups

LLDP

Support LLDP to allow switch to advise its identification and capability on the LAN

CDP

Cisco Discovery protocol for topology mapping

ITU G.8032

Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (single ring enhanced mode)
Support various ring/chain topologies
Includes train ring, auto ring, basic single ring, enhanced ring, multiple-VLAN ring
Enhanced G.8032 ring configuration with ease
Cover multicast & data packets protection

User friendly UI

  1. Auto topology drawing
  2. Topology demo
  3. DDM threshold monitoring with dB values***
  4. Complete CLI supported

PoE Management

  1. PoE Detection to check if PD is hang up then restart the PD
  2. PoE Scheduling to On/OFF PD upon routine time table
  3. Per-port PoE status including current, voltage, watt and temperature

Spanning Tree

Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree 16 MSTI

Quality of Service

The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4

Class of Service

Support IEEE802.1p class of service, per port provides 8 priority queues

MLD Snooping

Support IPv6 Multicast stream

Port Mirror

Support 3 mirroring types: “RX, TX and Both packet”

IGMP

Support IGMP snooping v1,v2,v3; Supports IGMP static route; 1024 multicast groups; IGMP router port ; IGMP query; GMRP

Static MAC-Port Bridge

Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application

Bandwidth Control

Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type, the limit rates are 0~100Mbps.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet. The packet filter rate can be set from 0 to 100Mbps
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.

Network Security

Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
802.1X access control for port based and MAC based authentication/MAC-Port binding
Management access control with priority
Ingress/Egress ACL L2/L3
SSL/ SSH v2 for Management
HTTPS for secure access to the web interface
TACACS+** for Authentication

Flow Control

Support Flow Control for Full-duplex and Back Pressure for Half-duplex

Protection

  1. Miss-wiring avoidance
  2. node failure protection
  3. Loop protection

System Log

Support System log record and remote system log server

SNMP Trap

Up to 10 trap stations; trap types including:

  1. Device cold start
  2. Authorization failure
  3. Port link up/link down
  4. DI/DO open/close
  5. Typology change(ITU ring)
  6. Power failure
  7. Environmental abnormal

DHCP

Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server

Mac based DHCP Server

Assign IP address by Mac

DNS

Provide DNS client feature

Diagnostic

Support Ping and DDM information

SNTP

Support SNTP to synchronize system clock in Internet

Environmental Monitoring

Internal sensor to detect temperature, voltage and current and send SNMP traps and emails if any abnormal events

Factory reset button & watch dog design

Factory reset button to restore back to factory default settings. Watch dog design can reboot switch automatically under certain circumstances

Firmware Update

Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade

USB Configuration
backup and restore

Supports text editable configuration file for system quick installation to backup and restore
USB dongle for automatic back up and editable restore

Auto Provision

To verify switch firmware with the latest or certain version

*Future Release
**Optional
***Optional DDM SFP required

DIMENSION

ORDERING INFORMATION

For optional power supply, add +DC, +DCI, +AC, or +HV to the part number.

P/N Model name Description
8380-601 IPGS-5424-DC 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch
Built-in 1x 12~56V DC power module + 1x optional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-600 IPGS-5424-AC 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch
Built-in 1x 100~240V AC IEC320 power conversion + 1x optional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-6011 IPGS-5424-DC-E 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch
Built-in 1x 12~56V DC power module + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C
8380-6001 IPGS-5424-AC-E 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch
Built-in 1x 100~240V AC IEC320 power conversion + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C


OPTIONAL ACCESSORIES - Power for System

Model name Description
EOTH000701 Isolation Power 100-240VAC, 120-370VDC 2.0A max, 47-63HZ
EOTH000702 Isolation Power 36-75VDC, 2.5A
EOTH000703 Isolation Power 100-240VAC IEC320 socket, 2.0A max, 47-63HZ
EOTH000704 Power Input Module 12-56VDC, 2.5A


OPTIONAL ACCESSORIES - DIN Rail Power for PoE

Model name Description
NDR-480 Series 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-240 Series 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-120 Series 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)
NDR-75 Series 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)


OPTIONAL ACCESSORIES - Mini GBIC (SFP)

Model name Description Model name Description
8330-162-V1 MINI GBIC 1000SX (LC/0.5KM) Transceiver 8330-186-V1 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310)
8330-163-V1 MINI GBIC 1000SX2 (LC/2KM) Transceiver 8330-187-V1 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-165-V1 MINI GBIC 1000LX (LC/10KM) Transceiver 8330-180-V1 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8340-0591-V1 MINI GBIC 1000LHX (LC/40KM) Transceiver 8330-182-V1 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8330-166-V1 MINI GBIC 1000XD (LC/50KM) Transceiver 8330-181-V1 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-169-V1 MINI GBIC 1000XD (LC/60KM) Transceiver 8330-183-V1 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-167-V1 MINI GBIC 1000ZX (LC/80KM) Transceiver 8330-184-V1 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-170-V1 MINI GBIC 1000EZX (120KM) Transceiver 8330-185-V1 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-168-V1 MINI GBIC 10/100/1000T (100m) Transceiver 8330-071-V1 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver
8330-060-V1 100Base FX 2KM, Multi-mode, LC Transceiver 8330-072-V1 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver
8330-065-V1 100Base FX 5KM, Multi-mode, LC Transceiver 8330-069-V1 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver
8330-061-V1 100Base LX 30KM, Single-mode, LC Transceiver 8330-068-V1 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver
8330-059-V1 100Base LX 60KM, Single-mode, LC Transceiver 8330-080-V1 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver
8330-197-V1 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) 8330-082-V1 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver
8330-198-V1 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) 8330-081-V1 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver
8330-195-V1 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) 8330-083-V1 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver
8330-196-V1 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) 8330-084-V1 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver
8330-188-V1 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) 8330-085-V1 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver
8330-189-V1 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) 8330-191-V1 Dual Speed SFP 100M/1000M-LX 10KM Transceiver
    All SFP P/N# ended with D are with DDM function