Datasheet
Hardware Manual
For latest firmware and web UI user manual, please contact us.
Lantech IPES-5408DFT is a high performance L2+ (Gigabit uplink) Ethernet switch with 8 10/100TX+2 10/100/1000T+2 Dual Speed 100/1000M SFP w/8 PoE 802.3af/at ports with total PoE budget 120W which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms covering multi-cast and data packets. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+**, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.
Up to 8 PoE at/af ports w/advanced PoE management
Compliant with 802.3af/at standard, the Lantech IPES-5408DFT is able to feed each PoE port up to 30 Watt, total PoE budget 120W. Lantech IPES-5408DFT supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE port can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.
Miss-wiring avoidance, Loop protection, Node failure protection
The IPES-5408DFT also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-5408DFT is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
Enhanced G.8032 Ring < 20ms for single ring recovery; auto ring, double ring, multi-chain covering multicast packets; MSTP with 16 MSTI
Lantech IPES-5408DFT features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI.
MRP (Media Redundancy Protocol) can be supported for industrial automation networks.
DHCP option 82 & Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.
QoS by VLAN for legacy devices
QoS by VLAN can allow switch to tag(C-tag and S-tag) QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.
802.1X security by MAC address
MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a port. By authenticating based on the host's source MAC address, the host is not required to run a user for the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC can be registered in the MAC address table of switch.
IGMPv3,GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.
Auto-provisioning for firmware/configuration update
The switch supports auto-provisioning for switch to auto-check the latest software image and configuration through TFTP server.
Auto topology drawing, User friendly UI, Complete CLI, DMI with dB value***
The user friendly UI, innovative auto topology drawing and topology demo makes IPES-5408DFT much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IPES-5408DFT supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.
Exported configuration text file; Factory reset button; CPU watchdog; Built-in RTC
The configuration file of Lantech IPES-5408DFT can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.
USB port & N-key** for back up, restore configuration and upgrade firmware
The built-in USB port can upload/download the firmware through USB dongle for switch replacement.
With optional N-key**, the configuration file can be mass auto backup, editable restored and auto upgrade firmware for easy maintenance.
2DI / 2DO relay to alarm and email/trap
The IPES-5408DFT DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPES-5408DFT will immediately send an email message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
Optional environmental monitoring** for switch inside information (-M model)
The environmental monitoring can detect switch overall temperature, voltage, total PoE load and current where can send the SNMP traps and email when abnormal.
DC powered input; Relay contact alarm
The Lantech IPES-5408DFT is designed with ±48VDC power input ranges from ±44V~±56VDC. Optional 12V model can accept power input from 9.5V~56VDC. Featured with relay contact alarm function, the IPES-5408DFT is able to connect with alarm system in case of power failure or port disconnection. The IPES-5408DFT also provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.
High reliability and extended working temperature
Lantech IPES-5408DFT features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.
Can be used in extreme environments with an operating temperature range of -40°C to 75°C.
Standards |
IEEE802.3 10Base-T Ethernet |
Switch Architecture |
Back-plane (Switching Fabric): 9.6Gbps |
Transfer Rate |
14,880pps for Ethernet port |
Mac Address |
16K MAC address table |
Jumbo frame |
10KB |
Connectors |
10/100TX: 8 x ports RJ-45 with Auto MDI/MDI-X function |
Network Cable |
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable |
Optical Cable |
1.25Gbps: |
LED |
Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red), RM(Green) |
DI/DO |
2 Digital Input (DI) : |
Operating Humidity |
5% ~ 95% (Non-condensing) |
Operating Temperature |
-20°C~60°C / -4°F~140°F (Standard model) |
Storage Temperature |
-40°C~85°C / -40°F~185°F |
Power Input |
48V model: ±44 ~ ±56VDC ; 12V model: 9.5~56VDC |
PoE Budget |
Max. 120W |
PoE pin assignment |
RJ-45 port # 1~ # 8 support IEEE 802.3at/af End-point. Per port provides up to 30W |
Case Dimension |
Metal case. IP-30, |
Weight |
900 g |
Installation |
DIN Rail and Wall Mount** Design |
EMI & EMS |
FCC Part 15 Class A |
Stability Testing |
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), |
Railway compliance |
EN 50121-4, |
MTBF |
797866.5 Hrs. (standards: IEC 62380) |
Warranty |
5 years |
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP MIB |
MIB |
ITU G.8032 |
Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (single ring) |
PoE Management |
PoE Detection to check if PD hangs then restart the PD; PoE configuration; PoE monitoring; PoE Scheduling to On/OFF PD upon routine time table |
Per Port PoE Status |
Enable/Disable, voltage, current, watts, temperature |
User friendly UI |
|
Port Trunk with LACP |
LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members |
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
CDP |
Cisco Discovery Protocol for topology mapping |
Environmental Monitoring** |
System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M model) |
VLAN |
Port Based VLAN |
RSTP/MSTP |
Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree with 16 MSTI |
Quality of Service |
The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4 |
Class of Service |
Support IEEE802.1p class of service, per port provides 8 priority queues |
MLD Snooping |
Support IPv6 Multicast stream |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Port Mirror |
Support 3 mirroring types: “RX, TX and Both packet” |
Network Security |
Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. |
IGMP |
Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP, QinQ, QOS by VLAN |
Static MAC-Port bridge |
Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application |
Bandwidth Control |
Support ingress packet filter and egress packet limit. |
RTC |
Built-in Real Time Clock to keep track of time always |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server(RFC3164) |
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
Protection |
|
SNMP Trap |
Up to 10 trap stations; trap types including:
|
DHCP |
Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server |
Mac based DHCP Server |
Assign IP address by Mac |
DNS |
Provide DNS client feature |
Diagnostic |
Support Ping and DDM information |
SNTP |
Supports Dual NTP server to synchronize system clock in Internet |
Firmware Update |
Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade |
Configuration backup & restore |
Supports text configuration file for system quick installation |
Auto Provision |
To verify switch firmware with the latest or certain version |
P/N | Model name | Description |
---|---|---|
8350-53841 | IPES-5408DFT | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; -20°C to 60°C |
8350-53851 | IPES-5408DFT-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; -40°C to 75°C |
8350-53861 | IPES-5408DFT-12V | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; -20°C to 60°C |
8350-53871 | IPES-5408DFT-12V-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; -40°C to 75°C |
8350-5384 | IPES-5408DFT-M | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; w/ Environmental monitoring; -20°C to 60°C |
8350-5385 | IPES-5408DFT-M-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; w/ Environmental monitoring; -40°C to 75°C |
8350-5386 | IPES-5408DFT-M-12V | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; w/ Environmental monitoring; -20°C to 60°C |
8350-5387 | IPES-5408DFT-M-12V-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; w/ Environmental monitoring; -40°C to 75°C |
Model name | Description |
---|---|
NDR-480 Series | 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-240 Series | 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-120 Series | 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
NDR-75 Series | 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
Model name | Description | Model name | Description |
---|---|---|---|
8330-162-V1 | MINI GBIC 1000SX (LC/0.5KM) Transceiver | 8330-186-V1 | 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310) |
8330-163-V1 | MINI GBIC 1000SX2 (LC/2KM) Transceiver | 8330-187-V1 | LTSFP-1000BX-20KM Transceiver (WDM 1550) |
8330-165-V1 | MINI GBIC 1000LX (LC/10KM) Transceiver | 8330-180-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1310) |
8340-0591-V1 | MINI GBIC 1000LHX (LC/40KM) Transceiver | 8330-182-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1550) |
8330-166-V1 | MINI GBIC 1000XD (LC/50KM) Transceiver | 8330-181-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1310) |
8330-169-V1 | MINI GBIC 1000XD (LC/60KM) Transceiver | 8330-183-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1550) |
8330-167-V1 | MINI GBIC 1000ZX (LC/80KM) Transceiver | 8330-184-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1490) |
8330-170-V1 | MINI GBIC 1000EZX (120KM) Transceiver | 8330-185-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1550) |
8330-168-V1 | MINI GBIC 10/100/1000T (100m) Transceiver | 8330-071-V1 | 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver |
8330-060-V1 | 100Base FX 2KM, Multi-mode, LC Transceiver | 8330-072-V1 | 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver |
8330-065-V1 | 100Base FX 5KM, Multi-mode, LC Transceiver | 8330-069-V1 | 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver |
8330-061-V1 | 100Base LX 30KM, Single-mode, LC Transceiver | 8330-068-V1 | 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver |
8330-059-V1 | 100Base LX 60KM, Single-mode, LC Transceiver | 8330-080-V1 | 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver |
8330-197-V1 | 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) | 8330-082-V1 | 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver |
8330-198-V1 | 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) | 8330-081-V1 | 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver |
8330-195-V1 | 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) | 8330-083-V1 | 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver |
8330-196-V1 | 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) | 8330-084-V1 | 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver |
8330-188-V1 | 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) | 8330-085-V1 | 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver |
8330-189-V1 | 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) | 8330-191-V1 | Dual Speed SFP 100M/1000M-LX 10KM Transceiver |
All SFP P/N# ended with D are with DDM function |
Model name | Description |
---|---|
MBAK19003 | Wall mount bracket for 74(W) x 105 (D) x 152 (H) mm Industrial switches |
MBAK19004 | 19” Rack Mounting Kit for 74x105x152mm/74x135x152mm Industrial Switch |
2020 © Lantech Communications Global, Inc. ALL Rights Reserved. Privacy Policy | Terms of Service