4- Modular-Slots w/4 x10G uplink L2+ Industrial Managed Ethernet Switch; DC/DCI/HV/AC input models


CE FCC WEEE RoHS2 10GbE speed PoE 802.3at/af 30W Environmental Monitoring USB L3L - Layer3 Lite L3 - Layer3


Hardware Datasheet   Software Datasheet   Hardware Manual  
For latest firmware and web UI user manual, please contact us.

OVERVIEW

Lantech I(P)GS-6300-2P is a high performance L2+ (All Gigabit) modular Ethernet switch with max 24/26port Gigabit + 4 10G uplink (total 28ports) w/(24 PoE 802.3af/at ports) which provides L2+ wire speed and advanced security function for network aggregation deployment.


Up to 24 PoE at/af ports w/advanced PoE management
Compliant with 802.3af/at standard, the PoE model is able to feed each PoE port up to 30 Watt at each PoE port for various IP PD devices. It supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.


Lantech OS3 Platform with complete L2 management and upgradable optional L3 & communication protocols
The switch runs Lantech OS3 platform which is powerful with complete Layer 2 management features and optional upgradable for future expansion, such as Layer 3 Lite, Layer 3, etc. To learn more about the Lantech OS3 Platform, please refer to Lantech OS3/OS4 platform


Enhanced cybersecurity features with IEC 62443-4-1 certification
Lantech OS3 platform is designed with high standard of cybersecurity to prevent the threats from network attack such as DDoS attacks. To ensure the safety and reliability of communication networks, Lantech develops our products under strict international security standard and is certified with IEC 62443-4-1 network security standard. To learn more about Lantech cybersecurity software solution, please refer to Lantech OS3/OS4 platform


Miss-wiring avoidance, node failure protection, Loop protection
The switch also embedded several features for strong and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, the switch being able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.


User friendly GUI, Auto topology drawing, Enhanced Environmental Monitoring
The user-friendly UI, innovative auto topology drawing and topology demo makes the switch much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line. It supports enhanced environmental monitoring for actual input voltage, current, ambient temperature and total power load.


Editable configuration file; USB port for import/export configuration
The configuration file of the switch can be imported and edited with word processor for the following switches to configure with ease. The USB port can import/export the configuration from/to USB dongle and also to upgrade firmware from USB dongle. TFTP/HTTP firmware upgrade is supported.


Event log & message; 2DI + 2DO; Factory default button
The switch provides 2DI and 2DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the outside alarm and switch will send alert information to IP network with traps. The factory reset button can restore the setting back to factory default.


Dual power DC/DCI/HV/AC inputs and dedicated PoE power source input
The chassis and modules of this switch are designed for easy maintenance and installation; It also supports dual DC/DCI power supplies (DC12~60V/ isolated 36~75VDC), dual HV (isolated 100~240VAC/120~370VDC) or dual AC (100~240VAC) input to increase the network reliability. The PoE model has independent PoE power source input by terminal block for connecting DC 48V PoE power source.


Industrial hardened design with high EFT and ESD protection
The switch features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. Featured with relay contact alarm function, the switch is able to connect with alarm system in case of power failure or port disconnection. It also provides 2000V EFT/SURGE and 6000V ESD CONTACT protection, which can reduce unstable situation caused by power line and Ethernet.


It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory applications. The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.


*Future release
**Optional

SPECIFICATIONS

Hardware Specifications

IEEE Standards

IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Ethernet
IEEE 802.3ab 1000Base-T Ethernet
IEEE 802.3z Gigabit Fiber
IEEE 802.3ae 10G Ethernet over Fiber
IEEE 802.3an 10G Copper
IEEE 802.3x Flow Control Capability
ANSI/IEEE 802.3 Auto-negotiation
IEEE 802.1Q VLAN
IEEE 802.1p Class of Service
IEEE 802.1X Access Control
IEEE 802.1D Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1x User Authentication (Radius)
IEEE 802.3at/af PoE (IPGS-6300-2P)

Switch Architecture

Back-plane (Switching Fabric): 128Gbps

Mac Address

16K MAC address table

Jumbo frame

10KB

Connectors

Max. 24 10/100/1000T RJ-45 with auto MDI/MDI-X function
Max 2 10G copper RJ45
Max 24 100M Mini-GBIC : SFP sockets
Max 28 1000M Mini-GBIC : SFP sockets
Max 4 10G Mini-GBIC : SFP + sockets
RS-232 console: Female DB-9
USB slot for upload/download config file
DIDO : 1x6pin terminal block

Network Cable

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable; EIA/TIA-568 100-ohm (100m)
1000Base-T: 4-pair UTP/STP Cat5E/6 cable;
10GBaseT:4-pair STP Cat6/6A/7 cable

Optical Cable

1Gbps:
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)
2.5Gbps
Multi mode: 0 to 300 m, 850 nm (50/125 μm);
Single mode: 0 to 2 km/ 15 km/ 40 km, 1310 nm (9/125 μm); 0 to 40 km/ 80 km/ 100km, 1550 nm (9/125 μm)
WDM 1Gbps:
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)
WDM 2.5Gbps
Single mode: 0 to 5 km/ 20 km/ 40 km/ 60 km, 1310 /1550nm (9/125 μm); 0 to 80 km, 1490/1550 nm (9/125 μm)
10Gbps
Multi mode: 0 to 300 m, 850 nm (OM3 50/125 μm);
Single mode: 0 to 10 km/ 20 km, 1310 nm (9/125 μm); 0 to 40 km/ 80km/ 100 km, 1550 nm (9/125 μm)
WDM 10Gbps
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1270/1330 nm (9/125 μm); 0 to 80km, 1490/1550 nm (9/125 μm)

LED

Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red); RM(Green)
Ethernet port: Link/Activity (Green), Speed (Green);
PoE** : Link/Act (Green); Mini-GBIC: Link/Activity (Green)

DI/DO

2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA

Operating Humidity

5% ~ 95% (Non-condensing)

Operating Temperature

-20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F(-E model)

Storage Temperature

-40°C~85°C / -40°F~185°F

Power Supply

One+ one** VAC/VDC input isolated 3000V 100~240VAC/120~370VDC(HV model)
One + one** VDC isolated 1600V 36~75VDC(DCI model)
Dual input for 12V~56VDC(DC model)
One + one** AC input AC100~240VAC(AC model)
PoE power dual input for 48VDC(IPGS-6300-2P)

PoE Budget

720W (from separate PoE power supply)
(50-56VDC input is recommended for 802.3at 30W applications)
Higher PoE budget can be applied upon request. **

PoE pin assignment

RJ-45 port # 1~#24 support IEEE 802.3at/af End-point, Alternative A mode.(IPGS-6300-2P & PoE modules)
Positive (VCC+): RJ-45 pin 1,2.
Negative (VCC-): RJ-45 pin 3,6.

Power Consumption

30W

Case Dimension

Metal case. IP-30
440mm(W)x325mm(D)x44mm(H)

Weight

2.9 kgs

Installation

Rackmount Design

EMI & EMS

FCC,
EN55032:2015
EN55024:2015
IEC 61000-4-2:2008
IEC 61000-4-3
IEC 61000-4-4:2012
IEC 61000-4-5:2017
IEC 61000-4-6:2015
IEC 61000-4-8:2009
IEC 61000-4-11:2017
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-6-4:2011
EN 61000-6-2:2005
EN55011:2016

MTBF

830589 hours (standards IEC 62380)

Warranty

5 years

Software Specifications

Lantech OS3 Platform

Learn more about Lantech OS3 Platform

*Future release
**Optional

DIMENSION

ORDERING INFORMATION

For optional power supply, add +DC, +DCI, +AC, or +HV to the part number. Note: the modules will be factory pre-installed.

P/N Model name Description
8380-208 IGS-6300-2P-HV 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x isolated AC/DC 100~240VAC/120V~370VDC power conversion + 1x optional power socket; -20°C to 60°C
8380-2081 IGS-6300-2P-HV-E 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x isolated AC/DC 100~240VAC/120V~370VDC power conversion + 1x optional power socket; -40°C to 75°C
8380-209 IGS-6300-2P-DCI 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x isolated DC 36~75VDC power supply + 1x optional power socket; -20°C to 60°C
8380-2091 IGS-6300-2P-DCI-E 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x isolated DC 36~75VDC power supply + 1x optional power socket; -40°C to 75°C
8380-202 IGS-6300-2P-AC 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x AC100~240VAC IEC320 power conversion + 1x optional power socket; -20°C to 60°C
8380-203 IGS-6300-2P-AC-E 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x AC100~240VAC IEC320 power conversion + 1x optional power socket; -40°C to 75°C
8380-205 IGS-6300-2P-DC 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x DC 12~56VDC power module + 1x optional power socket; -20°C to 60°C
8380-206 IGS-6300-2P-DC-E 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis;
Built-in 1x DC 12~56VDC power module + 1x optional power socket; -40°C to 75°C
8380-210 IPGS-6300-2P-HV 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x isolated AC/DC 100~240VAC/120V~370VDC power conversion + 1x optional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-2101 IPGS-6300-2P-HV-E 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x isolated AC/DC 100~240VAC/120V~370VDC power conversion + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C
8380-211 IPGS-6300-2P-DCI 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x isolated DC 36~75VDC power supply + 1x optional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-2111 IPGS-6300-2P-DCI-E 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x isolated DC 36~75VDC power supply + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C
8380-204 IPGS-6300-2P-AC 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x AC100~240VAC IEC320 power conversion + 1x optional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-2041 IPGS-6300-2P-AC-E 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x AC100~240VAC IEC320 power conversion + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C
8380-207 IPGS-6300-2P-DC 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x DC 12~56VDC power module + 1x optional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-2071 IPGS-6300-2P-DC-E 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis;
Built-in 1x DC 12~56VDC power module + 1x optional power socket + 1x 48VDC PoE power input; -40°C to 75°C


Modules for Slot 1-3

 
Note: the modules will be factory pre-installed.

P/N Model name Discription
8380-123 8x GIGA T Module 8x 10/100/1000T Module; -40°C to 75°C
8380-124 8x GIGA T-PoE at/af Module 8x 10/100/1000T PoE at/af Module; -40°C to 75°C
8380-125 8x SFP Module 8x Dual Speed SFP module for 100M SFP or Gigabit SFP; -40°C to 75°C


Modules for Slot 4

 
Note: the modules will be factory pre-installed.

8380-126 4x 10G SFP Module 4x 1G/2.5G/10G SFP Module for slot 4; -40°C to 75°C
8380-127 2 100M/1G/10G Copper + 2 100M/1G/2.5G/10G SFP+ Module 2x 100M/1G/10G Copper + 2 100M/1G/2.5G/10G SFP+ Module for slot 4 ; -40°C to 75°C


OPTIONAL ACCESSORIES - Software package

Please refer to Lantech OS3/OS4 platform


OPTIONAL ACCESSORIES - Power for System

Model name Description
EOTH000705 Isolation Power 100-240VAC, 120-370VDC 2.0A max, 47-63HZ
EOTH000702 Isolation Power 36-75VDC, 2.5A
EOTH000706 Isolation Power 100-240VAC IEC320 socket, 2.0A max, 47-63HZ
EOTH000704 Isolation Power 100-240VAC IEC320 socket, 2.0A max, 47-63HZ


OPTIONAL ACCESSORIES - DIN Rail Power for PoE

Model name Description
NDR-480 Series 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-240 Series 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-120 Series 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)
NDR-75 Series 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)


OPTIONAL ACCESSORIES - Mini GBIC (SFP)

Model name Description Model name Description
8330-162-V1 MINI GBIC 1000SX (LC/0.5km) Transceiver 8330-183-V1 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-163-V1 MINI GBIC 1000SX2 (LC/2km) Transceiver 8330-184-V1 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-165-V1 MINI GBIC 1000LX (LC/10km) Transceiver 8330-185-V1 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8340-0591-V1 MINI GBIC 1000LHX (LC/40km) Transceiver 8330-262D-V1 MINI GBIC 2.5G 850nm VCSEL (LC/0.3km) Transceiver
8330-166-V1 MINI GBIC 1000XD (LC/50km) Transceiver 8330-263D-V1 MINI GBIC 2.5G 1310nm FP (LC/2km) Transceiver
8330-169-V1 MINI GBIC 1000XD (LC/60km) Transceiver 8330-265D-V1 MINI GBIC 2.5G 1310nm DFB (LC/15km) Transceiver
8330-167-V1 MINI GBIC 1000ZX (LC/80km) Transceiver 8330-193D-V1 10G Base SFP+ SR, Multi-mode (LC/300m) Transceiver
8330-170-V1 MINI GBIC 1000EZX (120km) Transceiver 8330-194D-V1 10G Base SFP+ LR, Single-mode (LC/10km) Transceiver
8330-168-V1 MINI GBIC 1000T (100m) Transceiver 8330-209D-V1 10G Base SFP+ , Single-mode(10km) Transceiver (WDM 1270)
8330-188-V1 LTSFP-1000BX-10KM Transceiver (WDM 1310) 8330-210D-V1 10G Base SFP+ , Single-mode(10km) Transceiver (WDM 1330)
8330-189-V1 LTSFP-1000BX-10KM Transceiver (WDM 1550) 8330-200D-V1 10G Base SFP+ , Single-mode(20km) Transceiver (WDM 1270)
8330-186-V1 LTSFP-1000BX-20KM Transceiver (WDM 1310) 8330-201D-V1 10G Base SFP+ , Single-mode(20km) Transceiver (WDM 1330)
8330-187-V1 LTSFP-1000BX-20KM Transceiver (WDM 1550) 8330-202D-V1 10G Base SFP+ , Single-mode(40km) Transceiver (WDM 1270)
8330-180-V1 LTSFP-1000BX-40KM Transceiver (WDM 1310) 8330-203D-V1 10G Base SFP+ , Single-mode(40km) Transceiver (WDM 1330)
8330-182-V1 LTSFP-1000BX-40KM Transceiver (WDM 1550) 8330-206-V1 10G/5G/2.5G/1000Base-T SFP, 3.3V,30m (10G) 50m (2.5G/5G) 100m (1G); -10~70°C
8330-181-V1 LTSFP-1000BX-60KM Transceiver (WDM 1310) All SFP ended with D are with Diagnostic function