24 GT + 4 10G Copper + 2 10G QODC M12 Push-Pull X-coded (PoE) EN50155 Managed Ethernet Switch w/optioanl L3 & Cybersecurity, WVI input


pushpull PoE 802.3bt 90W Wide power input range with isolation PoE power budget extend power monitor OOB L3 - Layer3 PTP V2 IEC 62443-4-2 Auto Topology Drawing Open API MACsec Auto Feed Config IPv6 ready Lantech View EN50155 IEC 61375-2-5 ETBN EN45545-2  Fire & Smoke


Hardware Datasheet   Software Datasheet   Hardware Manual  
For latest firmware and web UI user manual, please contact us.

OVERVIEW

Lantech T(P)GS-H7624XFT is a high-performance OS5 managed Ethernet switch with 24 10/100/1000T + 4 100M/1G/2.5G/5G/10G Copper +2 1G/2.5G/5G/10G QODC Fiber switch (total 30 ports) w/ M12 X-coded Push-Pull lock connectors (IEC 61076-2-010). The OS5 platform supports L3/L2, IPv6/v4, NAT**, standardized ITU G.803 ring, IEC62443-4-2 certified cybersecurity, Macsec**, PTP v2** as well as ETBN TTDP**, TRDP* protocol suitable for the future-proof modern network.


Lantech OS5 platform is equipped with complete L2 management and L3 communication protocols incl. dynamic routing, multicast routing, hardware NAT and ETBN TTDP; optional PTP, MacSec to be upgradable
The switch runs on the Lantech OS5 platform which is powerful with complete Layer 2 management features and major L3 protocols inclusive of RIP, OSPF, PIM, DVMRP, IEC61375-2-5 (ETBN), TRDP* and hardware-based NAT. It also supports optional Macsec for authentication and encryption between two Macsec devices. The optional PTP V2 and gPTP support transparent clock, boundary clock and ordinary clocks with 2-step processing that synchronizes network time accuracy to sub-microseconds. To learn more about the Lantech OS5 Platform, please refer to Lantech OS5 platform


Certified cybersecurity development process with IEC 62443-4-1, and IEC 62443-4-2** certificate with physical tamper resistance and detection for integrity and authenticity of the boot process
Lantech OS5 platform is designed with a high standard of cybersecurity to prevent threats from network attacks. To ensure the safety and reliability of communication networks, Lantech software development is certified with IEC 62443-4-1 security process standards and the switch is also certified with IEC 62443-4-2**. The switch uses roots of trust to verify the integrity and authenticity of the firmware, software, and configuration data needed for the switch’s boot process. To learn more about Lantech cybersecurity software solutions, please refer to Lantech OS5 platform


Support Restful API for better switch performance; Auto-provisioning* for firmware/configuration update
The switch supports Restful API that uses JSON format to access and use data for GET, PUT, POST and DELETE types to avoid traditional SNMP management occupying CPU utilization. The OPEN API document format for Restful API can greatly improve central management efficiency for various applications including fleet management and AIOT. It also supports auto-provisioning for switch to auto-check the latest software image and configuration through TFTP server.


Optional IEC 61375-2-5/3-4 ETBN/ECN TTDP protocol, RNAT and proprietary DHCP and VLAN over TTDP
Lantech optional L3L/L3 license includes IEC 61375-2-5 and 3-4 ETBN standardized TTDP protocol that automatically assigns the switch IP address reflecting its location to adapt with various train-car arrangements of the operator’s plan. With RNAT (railway NAT), each car device's IP address can be routed to the specific server and proprietary DHCP and VLAN over TTDP to help manage fixed IP address per device as well as the segmentation of VLAN in ECN.


Redundant dual WVI power input w/ power transient, inrush current, polarity reverse and over-heat protection
The T(P)GS-H7624XFT WVI model accepts 16.8~137.5VDC dual inputs with galvanic isolation to PoE and all Ethernet ports. The switch incorporates a power protection circuit to safeguard against potential adverse effects and hazards from power transients (surges, spikes, power fluctuations). It is also designed to clamp inrush current and protect from polarity reversal damage. The switch will automatically disable power output when the switch ambient temperature is over 85°C and re-boot when the temperature is back to normal.


Up to 24 PoE at/af and 22 PoE ports include 20 IEEE 802.3at/af and 2 T4 PoE 802.3bt/at/af w/advanced PoE management and PoE galvanic isolation with max PoE budget, support Perpetual/Fast PoE
Compliant with 802.3 bt/at/af standard, the PoE model is able to feed 24 or 20 PoE ports up to 30 Watt@ and 2 T4 PoE IEEE 802.3bt to feed PoE up to 90 Watt@. The switch supports 120W PoE budget with an optional external PoE supply, it can provide up to a total 450W PoE output power. (-PEXT model) It supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow a pre-set power feeding schedule upon a routine timetable. Each PoE port can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI. Perpetual and Fast PoE provides immediate and continuous power to devices during PSE switch reboots. The PoE galvanic isolation provides insulation between the power input to PoE Ethernet ports, preventing cabling and grounding incidents from damaging the Ethernet switch. The efficiency of the galvanically decoupled voltage converters can reach above 90%.


Support RTC (Real Time Clock) with longevity golden capacitor
Our switch supports RTC which is powered by a golden capacitor, ensuring accurate real-time event logs for all times. Unlike traditional batteries, golden capacitors offer superior reliability, and longevity, without a need to change battery.


User-friendly GUI, Auto topology drawing, Enhanced Environmental Monitoring
The user-friendly UI, innovative auto topology drawing, and topology demo make the switch much easier to get hands-on. The complete CLI enables professional engineers to configure settings by command line. It supports real-time power monitoring for actual input voltage, current, switch ambient temperature and total power load.


Out-Of-Band management
OOB management allows a separate and secure method to access and manage the switch even when the primary network is inaccessible. (-OOB model)


Editable configuration file; USB port for import/export configuration
The configuration file of the switch can be imported and edited with a word processor for the following switches to configure with ease. The USB data port can import/export the configuration from/to the USB dongle and also to upgrade firmware. It supports USB console port that allows CLI access. It supports USB type-C console port that allows CLI access without an external RS232 adapter is required.


Event log & message; 2DI + 2DO; Factory default pin
The switch provides 2DI and 2DO. When disconnection of the specific port is detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the outside alarm and the switch will send alert information to IP network with traps. The factory reset pin can restore the setting to factory default.


Optional smart bypass protection on dual 10G copper ports
The bypass relay is set to bypass the switch to the next one when power is off to prevent network disruption. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network loss. Optional smart bypass (one pair) can be activated when switch encounters power failure or CPU hang. (-BT model)


EN50155, EN45545-2; EN61373 compliance
The IP54 aluminum alloy enclosure meets with EN60529 with M12 connectors for waterproofing. With EN50155 verification along with EN45545-2 Fire & Smoke compliance, this switch is ideally suited for railway on-board/trackside, vehicle, and other rugged applications. The switch operates under wide-ranging temperatures from -40°C to 70°C (-40°F to 158°F) (EN50155 T4).


*Future release
**Optional

SPECIFICATIONS

Hardware Specifications

Standards

IEEE802.3 10Base-T Ethernet
IEEE802.3u 100Base-TX
IEEE802.3ab 1000Base-T
IEEE802.3an 10Gbase-T
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE802.3ad Link Aggregation Control Protocol (LACP)
IEEE802.1AB Link Layer Discovery Protocol (LLDP)
IEEE802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet
Type 3 IEEE802.3bt Power over Ethernet
Type 4 IEEE802.3bt Power over Ethernet

Switch Architecture

Back-plane (Switching Fabric): 168Gbps

Mac Address

16K MAC address table

Jumbo frame

10KB

Connectors

10/100/1000T: 24 x M12 8-pole X-coded with Auto MDI/MDI-X function with Push-Pull connectors
100M/1G/2.5G/5G/10G Copper: 4x M12 8-pole X-coded port 25-30 with Push-Pull connectors
1G/2.5G/5G/10G FX: 2x ports Q-ODC OM3 with multi-mode fiber with Push-Pull connectors
Power Input connector: 1 x M12 5-pole Male K-coded
Reset/USB console/USB data: 1 x M12 8-pole A-coded Push-Pull connector
DIDO: 1 x M12 5-pole A-coded Push-Pull connector  
Out-Of-Band connector: M12 8-pole X-coded with Push-Pull connector  

Network Cable

1000Base-T: 4-pair STP Cat5E/6 cable;
10G Copper: 4-pair STP Cat6a/7 cable

LED

Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red)
100/1000T Ethernet port: Link/Activity (Green), Speed (Green);
R.M. indicator (Green)
Uplink 100M/1G/2.5G/5G/10G
Copper ports: Speed (100M/1G: Green; 2.5G/5G/10G: Orange)
Q-ODC fiber: Speed (1G: Green; 2.5G/5G/10G: Orange)
PoE: Link/Act (Green)

DI/DO

2 Digital Input (DI)
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output (DO): Open collector to 80 VDC, 50mA

Operating Humidity

5% ~ 95% (Non-condensing)

Operating Temperature

-40C~70C / -40F~158F (85°C operation for 10min.)

Storage Temperature

-40°C~85°C / -40°F~185°F

Power Supply

Dual DC input
WVI (16.8~137.5VDC)
T-code PoE power input:
54VDC (for PoE at/bt)

Inrush Current

6A

PoE Budget (PoE model)

Internal 120W
450W with external PoE power supply
(-PEXT model)

PoE pin assignment (PoE model)

-24 model:
M12 port #1~#24 (AT 30W)
-22 model:
M12 port #1~#20 (AT 30W)
M12 port #29~#30 (BT 90W)
support IEEE 802.3bt/at/af End-point, Alternative A mode

Power Consumption

Max. 65W excludes PoE load

Dimensions

IP54 Aluminum alloy case (wall mount):
390mm(W)x108.2mm(H)x225mm(D)

Weight

4.97kgs

Installation

Wall Mount Design

EMI & EMS

FCC Part 15 Class A
EN61000-6-2
EN61000-6-4
CE EN55032 Class A
CE EN55024
CE EN61000-4-2 (ESD) Level 3
CE EN61000-4-3 (RS) Level 3
CE EN61000-4-4 (EFT) Level 3
CE EN61000-4-5 ED3 (Surge) Level 3
CE EN61000-4-6 (CS) Level 3
CE EN61000-4-8 (Magnetic field) Level 3V

Verifications

EN50155/EN50121-3-2/EN50121-4;
EN 45545-1, EN 45545-2 Fire & Smoke verification

Stability Testing

EN61373 (Shock and Vibration)

MTBF

170,979 hrs. (standards: IEC 62380)

Warranty

5 years

Bypass**

One pair Bypass module on 10GT ports to pass to next switch in case of power failure and CPU fail

Software Specifications

Lantech OS5 Platform

Learn more about Lantech OS5 Platform

*Future release
**Optional

DIMENSION

-OOB-PEXT model

w/o -OOB-PEXT model

ORDERING INFORMATION

All model packages include M12 caps. For conformal coating add –C to Model Name. For optional bypass add –BT (one pair); For optional PTP add -PTP; for optional MacSec add -MacSec; For optional Out-Of-Band add -OOB; optional PoE power extension add -PEXT

P/N Model name Description
8361-030 TPGS-H7624XFT-24-54-WVI 24 10/100/1000T PoE at/af + 4 100M/1G/2.5G/5G/10G Copper + 2 1G/2.5G/5G/10G Q-ODC 300m M12 X-coded EN50155 OS5 Managed Ethernet Switch; 16.8V~137.5V dual inputs; IP54 wall mount design; -40°C to 70°C; w/ PoE & ethernet galvanic isolation
8361-0301 TPGS-H7624XFT-22-54-WVI 24 10/100/1000T w/20 PoE at/af + 4 100M/1G/2.5G/5G/10G Copper w/ 2 T4 PoE bt + 2 1G/2.5G/5G/10G Q-ODC 300m M12 X-coded EN50155 OS5 Managed Ethernet Switch; 16.8V~137.5V dual input; IP54 wall mount design; -40°C to 70°C; w/ PoE & ethernet galvanic isolation
8361-0302 TGS-H7624XFT-54-WVI 24 10/100/1000T + 4 100M/1G/2.5G/5G/10G Copper + 2 1G/2.5G/5G/10G Q-ODC M12 X-coded EN50155 OS5 Managed Ethernet Switch; 16.8V~137.5V dual input; IP54 wall mount design; -40°C to 70°C; w/ethernet galvanic isolation
8361-0303 TPGS-H7624XFT-22-54-WVI-PEXT-BT-C 24 10/100/1000T + 4 100M/1G/2.5G/5G/10G Copper + 2 1G/2.5G/5G/10G Q-ODC M12 X-coded EN50155 OS5 Managed Ethernet Switch; 16.8V~137.5V dual input; IP54 wall mount design; -40°C to 70°C; w/ethernet galvanic isolation; w/PoE power extension; w/one-pair bypass; w/conformal coating


OPTIONAL ACCESSORIES - Software package

Please refer to Lantech OS5 platform


OPTIONAL ACCESSORIES - Connector

Model name Description
4106-00000097-001
ECONM12-05K(F)-S-180
5 pin M12 (Female) K-coded 180 degrees screw type connector for power supply
ECONM12-08A(M)-180 8 pin M12 (Male) A-coded 180 degree crimp type connector for reset/console/USB
ECONM12-05A(M)-C-180 5 pin M12 (Male) A-coded 180 degree crimp type connector for DI/DO
ECONM12-08X(M)-SPEEDCON 8 pin M12 (Male) X-coded 180 degree crimp type connector for data, Ethernet CAT6A (10G), shielded, SPEEDCON


OPTIONAL ACCESSORIES - Cable

Model name Description
4106-00000096-001
ECABM12-05K(F)-90-1.5M
5 pin M12 (Female) K-coded 90 degrees 1.5M cable for power supply
ECABM12X83MSTP 8 pin M12 (Male) X-coded 180 degree RJ45 STP cable for data, shielded, 300cm
4106-00000006-001 Q-ODC 2 plug/LC multi-mode fiber, MM-OM3 300cm


OPTIONAL ACCESSORIES - Others

Model name Description
4106-00000100-001 8 pin M12 (Male) A-coded 180 degrees to USB Female/male plug, 150cm