Lantech 100Base Small Form Factor Pluggable (SFP) transceiver module series is specifically designed for the high performance integrated duplex data link over single-mode or multi-mode optical fiber. These transceiver modules are compliant with the SFP Multisource Agreement (MSA). With the hot pluggability, these modules offer an easy way to be installed into SFP MSA compliant ports at any time without the interruption of the host equipments operating online.
The high performance 850nm provides superior performance for Ethernet applications up to 2KM MMF optical links.
Parameter |
Symbol |
Min. |
Max. |
Unit |
Note |
Storage Temperature |
Ts |
-40 |
+85 |
°C |
|
Supply Voltage |
VccT, VccR |
-0.5 |
4.0 |
V |
|
Storage Relative Humidity |
RH |
5 |
95 |
% |
|
Parameter |
Symbol |
Min. |
Typ. |
Max. |
Unit |
Note |
Case Operating Temperature |
Tc |
-10 |
|
70 |
°C |
|
Supply Voltage |
Vcc |
3.15 |
3.3 |
3.45 |
V |
|
Supply Current |
Icc |
|
|
240 |
mA |
|
Parameter |
Symbol |
Min. |
Typ. |
Max. |
Unit |
Note |
|
Differential Data Output Voltage |
Vout, pp |
500 |
|
1200 |
mV |
|
|
Maximum Input Power |
PINMAX |
-3 |
|
|
dBm |
1 |
|
Receiver Sensitivity |
PINMIN |
|
|
-26 |
dBm |
1 |
|
Operating Center Wavelength |
λC |
770 |
|
870 |
nm |
|
|
LOS De-Assert |
LOSD |
|
|
-26 |
dBm |
|
|
LOS Assert |
LOSA |
-37 |
|
|
dBm |
|
|
LOS Hysteresis |
LOSVHY |
0.5 |
|
|
dB |
|
|
Optical Rise / Fall Timet |
tr / tf |
|
|
2 |
ns |
2 |
|
Receiver LOS Signal Output Voltage-Low |
LOSVL |
GND |
|
GND+0.5 |
V |
|
|
Receiver LOS Signal Output Voltage-High |
LOSVH |
2.4 |
|
Vcc |
V |
|
|
Notes: 1. With BER better than or equal to 1×10-12, measured in the center of the eye opening with 27 –1 PRBS 2.20% to 80% value |
Parameter |
Symbol |
Min. |
Typ. |
Max. |
Unit |
Note |
|
Differential Data Input Voltage |
VDIFF |
400 |
|
2000 |
mV |
|
|
Optical Launch Power |
PO |
-9 |
|
-3 |
dBm |
1 |
|
Optical Extinction Ratio |
ER |
9 |
|
|
dB |
|
|
Center Wavelength |
λC |
830 |
850 |
870 |
nm |
|
|
Spectral Width |
Δλ |
|
|
0.85 |
nm |
|
|
Optical Rise / Fall Timet |
tr / tf |
|
|
2 |
ns |
2 |
|
Optical Eye Mask |
|
IEEE802.3u |
|
||||
Transmit Disable Voltage |
VDIS |
2.0 |
|
Vcc |
V |
|
|
Transmit Enable Voltage |
VEN |
GND |
|
GDN+0.8 |
V |
|
|
Notes: 1. Coupling into a 62.5/125μm, NA=0.275 fiber. 2. 20% to 80% value |
*All dimensions are ±0.2mm unless otherwise specified
Part Number |
Wavelength |
Mode |
Link |
Temp. |
8330-073-V1 |
850nm |
Multi-mode |
2km |
-10~70°C |
8330-073E-V1 |
850nm |
Multi-mode |
2km |
-40~85°C |
2020 © Lantech Communications Global, Inc. ALL Rights Reserved. Privacy Policy | Terms of Service